Heavy Wall Structural Hollow Section

Send Inquiry
Heavy Wall Structural Hollow Section
Details
We manufacture heavy wall structural hollow sections in square (SHS), rectangular (RHS) and round (CHS) profiles. In our workshop, heavy wall means 12 mm wall and above, or a width-to-wall ratio below about 15. This is the product to choose when a smaller column must carry a bigger load, when the member is exposed to impact, or when fire protection cost matters.
Category
Hollow Section
Share to
Description

Tianjin Brisk Metalwork Co., Ltd. is one of the leading manufacturers and suppliers of heavy wall structural hollow section in China. We have world-leading production equipment and strong manufacturing capabilities. Please feel free to buy bulk durable heavy wall structural hollow section from our factory.

 

Our Product

Tianjin Brisk Steel focus on produce and supply hollow section and steel pipe

EN 10210 HOT FINISHED BOX SECTION
EN 10210 S275J0H SQUARE TUBE
EN 10210 SEAMLESS PIPE
EN 10210 STEEL PIPE FOR PRESSURE

What Heavy Wall Hollow Sections Do We Make?

 

Item What we supply
Profiles SHS, RHS, CHS
Wall thickness 12 mm to 40 mm (CHS), up to about 25 mm for SHS/RHS by size
Size range SHS/RHS up to 500 x 500 mm; CHS 21.3 to 630 mm OD
Grades S355 to S460 (J0/J2/K2, NH, MH as required)
Routes Cold-formed welded (EN 10219) for lighter heavy-wall sizes; hot-finished (EN 10210) for thicker walls
Lengths 6 m and 12 m, saw-cut to your list
Finishes Black, painted, hot-dip galvanized
Documents EN 10204 3.1 certificate, third-party inspection welcome

 

How Does Heavy Wall Give More Capacity in a Smaller Footprint?

 

When a column's width is limited by architecture, thickening the wall is the cleanest way to add capacity. Compare two options for the same load:

 

  300 x 300 x 10 250 x 250 x 16
Cross-section area about 11,600 mm2 about 14,980 mm2
Footprint 300 mm 250 mm (50 mm smaller each side)
Wall slenderness thin, local buckling can govern compact, local buckling unlikely

 

The thicker option has about 29% more steel area in a smaller outline. Compact walls also reach their full strength before the plate walls buckle, which gives engineers a more efficient design.

 

How Does Heavy Wall Reduce Fire Protection?

 

Fire protection demand follows the section factor, which is heated surface divided by steel volume. A thin-walled tube heats up quickly. A thick-walled one has more steel to heat for the same surface.

 

  • 300 x 300 x 10 has a section factor of about 103 per metre
  • 250 x 250 x 16 has a section factor of about 67 per metre

 

A lower section factor usually means a thinner intumescent film or less board cladding for the same fire rating, and less surface to coat. Your fire engineer confirms the final figure, and we supply the section data they need.

 

Where Does Heavy Wall Resist Damage Better?

 

A thick wall resists denting, local crushing and impact far better than a thin one. We supply it for:

 

  • Car park and loading dock columns exposed to vehicle contact
  • Crane and machinery frames
  • Port and platform structures
  • Piling frames and heavy supports
  • Transfer columns and heavy trusses in buildings
  • Concrete-filled columns, where the thick wall also confines the infill

 

What Trade-Off Comes With Heavy Wall?

 

As the wall gets thicker, the outer corner radius grows, and the flat face on a square or rectangular section gets narrower. This matters for gusset widths, cap plates and weld preparation. Give us your connection details and we confirm the real flat width of the chosen size, so the drawing and the tube agree. Heavy wall also costs more per metre, so we recommend it where strength, fire or impact governs, not everywhere.

 

How Do We Control Quality on Thick Wall Tube?

 

  • Ultrasonic thickness checks on each face at three positions along sampled pieces from every lot
  • Ultrasonic end-zone scan for lamination when the project requires it
  • Mechanical tests by heat lot, with test pieces taken per the standard, tied to heat numbers
  • Normalizing control on hot-finished sections, so properties are even around the section and through the wall
  • Weld seam inspection on welded tubes, with NDT
  • Dimensional checks of width, squareness, straightness and corner shape against your order
  • Every piece marked with grade, size, standard and heat number

 

What Does a Real Order Look Like?

 

A building contractor needed 24 transfer columns, 9 m tall, in a podium with a tight grid. The first design used 300 x 300 x 10 mm tube, but the column outline cut into a parking bay and the fire-protection schedule was heavy. The engineer moved to 250 x 250 x 16 mm S355J2H, which gave 29% more steel area, a 50 mm smaller outline and a section factor down from about 103 to 67 per metre.

 

We supplied the 24 columns with saw-cut ends, UT thickness records and heat-matched certificates. The columns fitted the grid, and the intumescent coating moved to a lower thickness band.

 

FAQ

Q: Can you bevel the ends of thick wall tube?

A: Yes. Tell us the bevel angle and root face and we cut them before shipment.

Q: Can heavy wall tube be hot-dip galvanized?

A: Yes. Tell us the member length early, so vent holes and dipping are planned before production.

Q: Do you supply impact-tested grades?

A: Yes. J2, K2 and NH grades are available for low-temperature service.

Q: Can you supply a section that is not on your list?

A: Send us the size and wall. We confirm whether we can make it or suggest the nearest standard size.

Contact now

MACHINE EQUIPMENT
500X500 Hollow section production lines
200X200 HOLLOW SECTION PRODUCTION LINES
UNCOILING PROCESS

Hot Tags: heavy wall structural hollow section, China heavy wall structural hollow section manufacturers, suppliers, factory, ASTM A500 GR C COLD FORMED HOLLOW SECTION, hollow section application, hollow section fluctuation, hollow section repair, Hot Finish Hollow Section, import of hollow section

Send Inquiry